Contec Multi Parameter Patient Monitor (TFT 12.1") Touch Screen

Contec Multi Parameter Patient Monitor (TFT 12.1") Touch Screen

Contec Multi Parameter Patient Monitor (TFT 12.1") Touch Screen

Brand :Contec
Product Code :CMS7000
Reward Points :479
Availability :In Stock
  • Rs.47,999

    & FREE shipping
  • Price in reward points : 47999

Contec Multi Parameter Patient Monitor (TFT 12.1") Touch Screen

Features

12.1” Colour TFT LCD display with waveforms upto 8 Channels Portable, streamline handle design Monitor measures from Adult to Neonates Graphic and tabular Trend for 96 hours for all parameters Multi Screen format Audible and Visual alarms with adjustable alarm ranges Powerful data management and storage capacity Manual or Automatic NIBP measuring with 500 unit memory Rechargeable battery backup Weight : 4.5Kg approx.


Respiration

Method: RA-LL impedance
Measurement range: Adult: 0~120 rpm, paediatric/neonatal: 0-150 rpm
Apnea alarm: YES


Temperature

Resolution: 0.1 0C
Channel: Dual-channel
Measurement range: 0-50 0C


IBP (Ungradable)
Channel: 2 Channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: 10~300 mmHg


ECG
5-lead or 12-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; avR; avL; avF; Vx; CAL
Gain selection: 12.5 mm/s, 25 mm/s, 50 mm/s
Accuracy: +1 bpm or +1%, whichever is greater
Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
Calibration signal: 1 m V+5%
Operation modes: Diagnostic, Monitor, Surgery
Heat rate range: Adult 15-300 bpm Paediatric/ Neonatal: 15-350 bpm
Measurement range: -2.0mV~2.0mV

S-T detection: YES, Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable


NIBP
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270 mmHg
Over- pressure protection: YES
Resolution: 1 mmHg
Accuracy: The mean error shall be less than +5 mmHg, the standard deviation shall be less than +8 mmHg
Alarm: Systolic, Diastolic, Mean


SpO2
Measurement range: 0-100%
Accuracy: +2%(70~100%); 0~69% unspecified
Alarm range: 0-100%